Slovenia Duct Damper

Product NameSlovenia Duct Damper
MaterialPlastic,ABS,PVC or other material
ColorWhite or custom color
StandardChina standard
SizeCustomized
MOQ10
PackagingStandard packaging
Delivery30day
  • Lindab - We simplify construction

    The damper can be used for regulating at rare occations. There is a separate assembly, measuring, balancing and maintenance instruction for this product. Ø 80–315 fullfills pressure class C in closed position.

    Ask For Quote Details
  • Dampers and Actuators Catalog - Johnson Controls

    to coordinate with the duct work contractor for the needed frame connection. Multi-section dampers are typically required when the damper size exceeds 48 inches wide or 60 inches high. Single dampers are not usually made larger than 48 x 76 or 60 x 72 inches for ease in shipping and handling and for construction rigidity. Coupling

    Ask For Quote Details
  • Ventilation damper, Lindab Air duct systems, Ventilation

    Dampers are installed in ventilating equipment for various purposes, such as: regulating, shut off, motorized, constant flow and variable flow. Flow meters are used to decide airflow rate in a duct system.

    Ask For Quote Details
  • How can you have balancing dampers in a grease duct

    Automated balancing dampers that are installed on a common duct system with multiple hoods connected have been proven to increase the savings that may be realized by the use of a demand control ventilation system by as much as 50% over non-damper systems.

    Ask For Quote Details
  • Butterfly Damper, 8 In Duct Diameter. Control Damper,8

    Premium 5" In-Line Duct Back Draft Damper Stop Drafts from Bath and Kitchen Fans. $30.99 + $5.00 Shipping

    Ask For Quote Details
  • Duct Dampers | McMaster-Carr

    In the event of a fire, these dampers automatically stop airflow through duct. Furnace Draft Dampers Also known as barometric dampers, these dampers improve furnace performance by automatically opening and closing to maintain consistent airflow despite changing environmental conditions.

    Ask For Quote Details
  • IRIS Dampers - Continental Fan

    The IRIS damper represents a resistance to airflow in a duct, as do the duct and fittings. Selecting an IRIS damper is simple. In the case of an existing duct, choose an IRIS damper to match the duct size. Alternatively, use the IRIS damper selection curves on pages 4 5 of the PDF Brochure.

    Ask For Quote Details
  • Fire Smoke Dampers - Motorized Fire Damper | KAD

    During power failure dampers that are equipped with pneumatic actuator returns the damper to closed position. For remote monitoring the damper and regular testing of the damper function should be connected to a central control. The motorized fire dampers can form part of a “Fire strategy” and use to ventilate pressurized escape routes.

    Ask For Quote Details
  • Products | www.systemair.com

    Smoke control dampers are fitted with actuator without spring therefore they have two safety positions, “open” and “closed” and require power supply even in the event of fire. To fit todays construction needs the Fire Dampers are produced in different sizes and shapes.

    Ask For Quote Details


Our Location

Contact Us

Boda Aluminum Products Co.,LTD

Address: Jingjiang, Taizhou City
Jiangsu Province, China
Zip code - 214500
Telephone: +81 18262317598
E-mail: JINGJIANGBODA@YEAH.NET